In column Chromatography, the moving phase is:
(A) The substances which are to be separated
(B) Eluent
(C) Adsorbent
(D)Mixture of eluent and substances to be prepared.
Answer
524.7k+ views
Hint: Column chromatography method used to isolate a single chemical compound from a mixture. Chromatography is used to separate substances based on differential adsorption of compounds to the adsorbent. Compounds move through the columns allowing them to be separated into fractions by the difference in their rates.
Complete step by step solution:
-When the mixture that needs to be separated is introduced from the top of the column, the movement of the individual components of the mixture is at different rates.
-The components with lower adsorption and affinity to stationary phase travel faster when compared to the greater adsorption and affinity with the stationary phase.
-The components that are fast are removed first whereas the components that are slow are eluted out last.
-The adsorption of solute molecules to the column occurs in a reversible manner that is repeated ever after completion. The rate of the movement of the components is expressed as:
$\mathrm{R}_{\mathrm{f}}=$ the distance travelled by solute/ the distance travelled by the solvent
$\mathrm{R}_{\mathrm{f}}$ is the retardation factor.
-Now, let us discuss the moving phase:
It is a mixture of the eluent and the substances to be prepared.
It acts as a solvent where the sample mixture can be introduced in the column.
It acts as a developing agent which helps in the separation of components in the sample to form bands.
It acts as an eluting agent where the components that are separated during the experiment are removed from the column
Hence, the answer is option (B).
Note: The polarity of the solvent which is passed through the column affects the relative rates at which compounds move through the column. Polar solvents can effectively go through with the polar molecules of a mixture for the polar sites on the adsorbent surface and will also better solvate the polar molecules.
Complete step by step solution:
-When the mixture that needs to be separated is introduced from the top of the column, the movement of the individual components of the mixture is at different rates.
-The components with lower adsorption and affinity to stationary phase travel faster when compared to the greater adsorption and affinity with the stationary phase.
-The components that are fast are removed first whereas the components that are slow are eluted out last.
-The adsorption of solute molecules to the column occurs in a reversible manner that is repeated ever after completion. The rate of the movement of the components is expressed as:
$\mathrm{R}_{\mathrm{f}}=$ the distance travelled by solute/ the distance travelled by the solvent
$\mathrm{R}_{\mathrm{f}}$ is the retardation factor.
-Now, let us discuss the moving phase:
It is a mixture of the eluent and the substances to be prepared.
It acts as a solvent where the sample mixture can be introduced in the column.
It acts as a developing agent which helps in the separation of components in the sample to form bands.
It acts as an eluting agent where the components that are separated during the experiment are removed from the column
Hence, the answer is option (B).
Note: The polarity of the solvent which is passed through the column affects the relative rates at which compounds move through the column. Polar solvents can effectively go through with the polar molecules of a mixture for the polar sites on the adsorbent surface and will also better solvate the polar molecules.
Recently Updated Pages
Physics and Measurement Mock Test 2025 – Practice Questions & Answers

NCERT Solutions For Class 5 English Marigold - The Little Bully

NCERT Solutions For Class 12 Maths Three Dimensional Geometry Exercise 11.1

NCERT Solutions For Class 11 English Woven Words (Poem) - Ajamil And The Tigers

NCERT Solutions For Class 6 Hindi Durva - Bhaaloo

NCERT Solutions For Class 12 Physics In Hindi - Wave Optics

Trending doubts
1 ton equals to A 100 kg B 1000 kg C 10 kg D 10000 class 11 physics CBSE

Difference Between Prokaryotic Cells and Eukaryotic Cells

One Metric ton is equal to kg A 10000 B 1000 C 100 class 11 physics CBSE

1 Quintal is equal to a 110 kg b 10 kg c 100kg d 1000 class 11 physics CBSE

Proton was discovered by A Thomson B Rutherford C Chadwick class 11 chemistry CBSE

Draw a diagram of nephron and explain its structur class 11 biology CBSE